Posted: Sun Jul 03, 2005 6:30 am Post subject: Negative hconn is transferred in MQCMIT Entrypoint
Novice
Joined: 13 Feb 2005 Posts: 12
Hi all,
I'm using the MTS sample provided by IBM (Tools\mts\Samples) [windows server] and trying to get the its events by using the sample API exit (Tools\c\Samples\Bin\amqsaxe.dll).
I see somehow that the CmitAfter and CmitBefore Entrypoint gets negative hconn parameter (hconn = -2).
Note that the Entrypoints before and after the mentioned get correct hconn value!