Posted: Fri Oct 01, 2004 9:32 am Post subject: ExecutionServer Instance Stopped with an Error.
Centurion
Joined: 17 Oct 2003 Posts: 123
Guys,
My Execution Server Instance was stopped with an Error FMC12240E. Nothing was written in fmcsys.log. When I run configuration Utility in debug mode, I found two errors
FMC34412E: The IPCC base address FMCQM for Queue Manager 8 conflicts with Java 2
FMC34032E: Cannot load TP Monitor library MQ: A file or directory in the path name does not exist (rc = 2).
Currently work flow is running. Can you please tell me what could be the reason for the above errors.
I am using AIX.
WF 3.4.5
MQ 5.3 csd 7
DB2 8.1
In qm.ini file you need to set a value for IPCCBASEADDRESS
It can be from 4 to 12 or something. Normally it is recommended to use 12.
Do a search in this forum for IPCCBASEADDRESS and also on IBM site.
Actually this was also documented in previous readme file of workflow supportpacks.
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum