Posted: Tue Jun 11, 2013 8:58 pm Post subject: XA setup- MQ queue manager start error
Centurion
Joined: 21 Aug 2006 Posts: 141
i am trying to setup XA MQ queue manager with oracle in windows 7 64 bit.Broker version 8.0.01 64 bit and MQ version 7.1.0.0 32 bit and oracle 11g express edition. when i configure the Queue manager oracle switch file (Also i copied the file in in default exit path) i am getting error when i start the queue manager.
I did both for 32 bit and 64 bit oracle switch file ukora24.dll with path and without path just to try and getting error in either case. I am getting the below error.
AMQ7622: WebSphere MQ could not load the XA switch load file for resource
manager 'oraxa'.
EXPLANATION:
An error has occurred loading XA switch file C:\IBM\MQSI\8.0.0.1\bin\ukora24.dll. If the
error occurred during startup then the queue manager will terminate. At all
other times the queue manager will continue without this resource manager
meaning that it will no longer be able to participate in global transactions.
The queue manager will also retry the load of the switch file at regular
intervals so that the resource manager will be able to participate again should
the load problem be resolved.
ACTION:
Look for a previous message outlining the reason for the load failure. Message
AMQ6175 is issued if the load failed because of a system error. If this is the
case then follow the guidance given in message AMQ6175 to resolve the problem.
In the absence of prior messages or FFST information related to this problem
check that the name of the switch load file is correct and that it is present
in a directory from which it can be dynamically loaded by the queue manager.
The easiest method of doing this is to define the switch load file as a
fully-qualified name. Note that if the queue manager is still running it will
need to be restarted in order that any changes made to its configuration data
can be picked up.
in the info center, for ukora.dll 32 bit it is advised to point to broker instal directory/bin/samples/xatm.
Still i have the switch file loading problem.
i see in the log files error AMQ6175. which says that exit path containing brackets windows can not resolve which was fix at MQ 6. level.
Then changed the default exit path from QM stanza and placed the dll file and changed switch file path in the configuration
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum