RSS Feed - WebSphere MQ Support
|
RSS Feed - Message Broker Support
|
 |
|
32-bit WMB 7.0.0.1 with 64-bit DB2 9.7 on 64-bit Windows 7 |
« View previous topic :: View next topic » |
Author |
Message
|
capistrano |
Posted: Tue Jul 05, 2011 9:08 am Post subject: 32-bit WMB 7.0.0.1 with 64-bit DB2 9.7 on 64-bit Windows 7 |
|
|
 Novice
Joined: 28 Jun 2005 Posts: 13 Location: Dublin
|
I had WMB 7, DB2 9.7 and Windows 7 all working on 64 bit. Then I had to use WTX 8.3 with WMB 7 and I couldn't deploy flows with the WTX node onto the 64-bit broker. Some googling told me that WTX on windows is only 32 bit and therefore I need to use a 32-bit WMB. So I uninstalled my 64-bit WMB 7 and installed the 32-bit WMB 7. After reinstalling WTX I could then deploy flows with the WTX node.
However, this broke my DB connectivity. I now get the following ODBC error:
[Microsoft][ODBC Driver Manager] The specified DSN contains an architecture mismatch between the Driver and Application'
So my question is: does anyone know if I can connect to a 64-bit DB2 instance from a 32-bit WMB 7 instance running on Windows 7? And if so how?
Any help appreciated. I've tried creating the ODBC data source using the different tools outlined in http://support.microsoft.com/kb/942976, but I still got the same error. |
|
Back to top |
|
 |
lancelotlinc |
Posted: Tue Jul 05, 2011 9:19 am Post subject: |
|
|
 Jedi Knight
Joined: 22 Mar 2010 Posts: 4941 Location: Bloomington, IL USA
|
If I had a choice, I would remove WTX. You can do everything you need to do with the base product without WTX.
If that is not an option, ask your DBA to install 32-bit ODBC driver. _________________ http://leanpub.com/IIB_Tips_and_Tricks
Save $20: Coupon Code: MQSERIES_READER |
|
Back to top |
|
 |
Vitor |
Posted: Tue Jul 05, 2011 9:24 am Post subject: Re: 32-bit WMB 7.0.0.1 with 64-bit DB2 9.7 on 64-bit Windows |
|
|
 Grand High Poobah
Joined: 11 Nov 2005 Posts: 26093 Location: Texas, USA
|
capistrano wrote: |
So my question is: does anyone know if I can connect to a 64-bit DB2 instance from a 32-bit WMB 7 instance running on Windows 7? And if so how? |
I know I gave up trying to get a 64-bit version of WMB to talk to a 32-bit database because I couldn't find an ODBC driver/configuration they both liked.
I was able to give up because my upgrade to WMBv7 is now scheduled after the platform upgrade to 64-bit (Win2008 I believe) and after the database has gone to 64-bit as a consequence. _________________ Honesty is the best policy.
Insanity is the best defence. |
|
Back to top |
|
 |
capistrano |
Posted: Wed Jul 06, 2011 1:47 am Post subject: |
|
|
 Novice
Joined: 28 Jun 2005 Posts: 13 Location: Dublin
|
Thanks for the replies.
I upgraded DB2 9.7 to fix pack 4 and recreated the 32-bit ODBC data sources using the application %WINDIR%\SysWOW64\odbcad32.exe and now it works! |
|
Back to top |
|
 |
|
|
 |
|
Page 1 of 1 |
|
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum
|
|
|
|