Posted: Thu Mar 19, 2009 5:09 am Post subject: WTX node problem
Centurion
Joined: 14 Mar 2009 Posts: 108
Hello All,
I have a problem with WTX node.
I have developed flow
Mqinput ------>compute----->WTX node
My requirement is , i need to send the data in XML format with 2 fields.
One the filename and 2nd one is The data which i have received.
I am able to pass the data and file name to WTX node.
But the problem is once data is propagates to WTX node it has failed .it showed in the exceptionlist as " state Error and Value is not Valid ".
then after i have developed 2 flows
1. flow
Mqinput ---->compute ---> Mqoutput
2.flow
Mqinput--->WTX.
now i am able to process the data to WTX andd it does not show any exception and errors.
But My requirment is to send the to WTX node directly from the compute node.
Am i am going to do anything compute node before sending it to WTX node.
it has failed .it showed in the exceptionlist as " state Error and Value is not Valid ".
Sounds wrong to me, but I'm not an expert. Please get more info about the error from user trace / system log / event viewer / rest of exception list.
I'll see whether the local WTX experts have any suggestions.
To add to what kamy said, WTX needs BLOB Input from Message Broker and you have to be careful that you set the properties folder to the right CCSID and Encoding.
And like what Kimbert has suggested you should be able to pass the control directly from the Compute node unless you have an underlying error.