PostPosted: Thu Dec 20, 2007 7:58 am    Post subject: Restricting access to commands within MQSC Reply with quote

Novice

Joined: 11 Jun 2007
Posts: 17

I would like to restrict access for a particular set of users so that they can only do the following within the MQSC command interpreter

1 stop and start channels
2 display channel and queue attributes
3 reset channel sequence numbers

How can I accompolish this?

Thanks,

Craig
Back to top
View user's profile Send private message
Gaya3
PostPosted: Thu Dec 20, 2007 8:05 am    Post subject: Reply with quote

Jedi

Joined: 12 Sep 2006
Posts: 2493
Location: Boston, US

Have a look of this

http://www.ibm.com/developerworks/websphere/techjournal/0711_col_wyatt/0711_col_wyatt.html


Regards
Gayathri
_________________
Regards
Gayathri
-----------------------------------------------
Do Something Before you Die
Back to top
View user's profile Send private message
jefflowrey
PostPosted: Thu Dec 20, 2007 8:53 am    Post subject: Reply with quote

Grand Poobah

Joined: 16 Oct 2002
Posts: 19981

Don't give them runmqsc access.

http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg24000686&loc=en_US&cs=utf-8&lang=en
_________________
I am *not* the model of the modern major general.
Back to top
View user's profile Send private message
craig0
PostPosted: Thu Dec 20, 2007 10:48 am    Post subject: Reply with quote

Novice

Joined: 11 Jun 2007
Posts: 17

Unfortunately that wrapper utility is not available for the HP Nonstop platform





jefflowrey wrote:
Don't give them runmqsc access.

http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg24000686&loc=en_US&cs=utf-8&lang=en
Back to top
View user's profile Send private message
jefflowrey
PostPosted: Thu Dec 20, 2007 10:58 am    Post subject: Reply with quote

Grand Poobah

Joined: 16 Oct 2002
Posts: 19981

craig0 wrote:
Unfortunately that wrapper utility is not available for the HP Nonstop platform


Well. Contact the author...

Or consider using a properly secured and scoped MQ Explorer connection, and ms0s.

That is, assuming that HP Nonstop has a command server? I confess that I haven't personally done any testing against that platform.
_________________
I am *not* the model of the modern major general.
Back to top
View user's profile Send private message
craig0
PostPosted: Thu Dec 20, 2007 12:51 pm    Post subject: Reply with quote

Novice

Joined: 11 Jun 2007
Posts: 17

So just to confirm then there is no facility to restrict access within MQSC?

if a user has the ability to run MQSC then they have full access to administer queues, channels etc???

I am not familiar with MQ explorer, but will look into it.

Thanks,

Craig
Back to top
View user's profile Send private message
jefflowrey
PostPosted: Thu Dec 20, 2007 1:24 pm    Post subject: Reply with quote

Grand Poobah

Joined: 16 Oct 2002
Posts: 19981

Runmqsc bypasses the security checking provisions, as far as I understand it. If you can run the command, you can do anything.

Using PCF messages instead, ala MQ Explorer, uses the Command Server, which does check the user id on the messages being sent.

Again, I don't know about HP Nonstop. Maybe one of the regulars who does will kindly correct where I'm wrong.
_________________
I am *not* the model of the modern major general.
Back to top
View user's profile Send private message
craig0
PostPosted: Thu Dec 20, 2007 2:44 pm    Post subject: Reply with quote

Novice

Joined: 11 Jun 2007
Posts: 17

Thanks very much.

The Nonstop does run a command server under Pathway so maybe this will work with the MQ Explorer. I'll look into it.
Back to top
View user's profile Send private message
fjb_saper
PostPosted: Fri Dec 21, 2007 5:31 am    Post subject: Reply with quote

Grand High Poobah

Joined: 18 Nov 2003
Posts: 20756
Location: LI,NY

You can also have the users use MO71 / MO72(mqsc) and specify the user on the channel's mcauser so that the access is restricted to what you will allow. Again this makes use of a client connection and the command server.

MO71's security features will allow you to restrict access to connection configuration. You can then use a wrapper for MO72 (-g -m) and have the users use that

Enjoy
_________________
MQ & Broker admin
Back to top
View user's profile Send private message Send e-mail
Display posts from previous:   
Post new topic  Reply to topic Page 1 of 1

MQSeries.net Forum Index » General IBM MQ Support » Restricting access to commands within MQSC
Jump to:  



You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
Protected by Anti-Spam ACP
 
 


Theme by Dustin Baccetti
Powered by phpBB © 2001, 2002 phpBB Group

Copyright © MQSeries.net. All rights reserved.