Author |
Message
|
kundan20kumar |
Posted: Fri Mar 16, 2007 2:01 pm Post subject: sender channel gets down |
|
|
Newbie
Joined: 16 Mar 2007 Posts: 2
|
Hi,
I have installed and configured Mq series on windows server . it worked fine initially but after some time my sender channel gets inactive very frequently and each time I need to start it mannually . what are checks do I need to Put to rectify this problem?
anybody pls help.
Thanks, _________________ Regards,
Purnanand |
|
Back to top |
|
 |
vennela |
Posted: Fri Mar 16, 2007 2:07 pm Post subject: |
|
|
 Jedi Knight
Joined: 11 Aug 2002 Posts: 4055 Location: Hyderabad, India
|
You have to setup channel triggering |
|
Back to top |
|
 |
kevinf2349 |
Posted: Fri Mar 16, 2007 6:32 pm Post subject: |
|
|
 Grand Master
Joined: 28 Feb 2003 Posts: 1311 Location: USA
|
......and (just for completeness) you could set the disconnect interval to 0 to ensure it nevers goes inactive again unless it is stopped manually.
I mention this just for completeness and not as a recommendation unless you have an application that can't tolerate the extra time for the channel to become active.
We trigger all our SNR channels and allow them to become inactive after a period of inactivity. It works fine for all out applications.
Setting a disconnect interval does have it's drawback and a search of this site will reveal a wealth of disussion about the pro's and cons of dscint and triggered channels. |
|
Back to top |
|
 |
Bill.Matthews |
Posted: Sat Mar 17, 2007 5:26 pm Post subject: |
|
|
 Master
Joined: 23 Sep 2003 Posts: 232 Location: IBM (Retired)
|
|
Back to top |
|
 |
kundan20kumar |
Posted: Sat Mar 17, 2007 11:38 pm Post subject: |
|
|
Newbie
Joined: 16 Mar 2007 Posts: 2
|
Thanks to all of u for your great and quick support .I got that problem solved .
would definetely be posting some other Doubts to all of you.
Pls if anybody having other links related to this topic pls post the same to me. _________________ Regards,
Purnanand |
|