RSS Feed - WebSphere MQ Support
|
RSS Feed - Message Broker Support
|
 |
|
V6 Toolkit installtion issue |
« View previous topic :: View next topic » |
Author |
Message
|
pfaulkner |
Posted: Tue Oct 31, 2006 8:36 am Post subject: V6 Toolkit installtion issue |
|
|
Master
Joined: 18 Mar 2002 Posts: 241 Location: Colorado, USA
|
I am trying to install the 6.0.1.1 toolkit on a windows box that currently has RAD 6.0.0.1 installed and getting this exception during the install.
(Oct 31, 2006 11:00:13 AM), Install, com.ibm.rational.cdi.archive.CDIInstallArchive, err, ProductException: (error code = 601; message="err"; additional data = [b_webt_shared_win32:com.ibm.rational.cdi.exception.CDIException: Cannot load the referenced location for b_webt_shared_win32.])
STACK_TRACE: 12
ProductException: (error code = 601; message="err"; additional data = [b_webt_shared_win32:com.ibm.rational.cdi.exception.CDIException: Cannot load the referenced location for b_webt_shared_win32.])
at com.ibm.rational.cdi.archive.CDIInstallArchive.install(CDIInstallArchive.java:390)
at com.installshield.product.service.product.PureJavaProductServiceImpl.installProductAction(PureJavaProductServiceImpl.java:1916)
at com.installshield.product.service.product.PureJavaProductServiceImpl$InstallProduct.getResultForProductAction(PureJavaProductServiceImpl.java:5195)
at com.installshield.product.service.product.InstallableObjectVisitor.visitComponent(InstallableObjectVisitor.java:369)
at com.installshield.product.service.product.InstallableObjectVisitor.visitInstallableComponents(InstallableObjectVisitor.java:333)
at com.installshield.product.service.product.InstallableObjectVisitor.visitProductBeans(InstallableObjectVisitor.java:133)
at com.installshield.product.service.product.PureJavaProductServiceImpl$InstallProduct.install(PureJavaProductServiceImpl.java:4563)
at com.installshield.product.service.product.PureJavaProductServiceImpl$Installer.execute(PureJavaProductServiceImpl.java:3758)
at com.installshield.wizard.service.AsynchronousOperation.run(AsynchronousOperation.java:41)
at java.lang.Thread.run(Thread.java:566)
Anyone seen this before? |
|
Back to top |
|
 |
ADV |
Posted: Tue Apr 24, 2007 9:21 am Post subject: How did u fix this? |
|
|
Apprentice
Joined: 24 Apr 2007 Posts: 44 Location: Boston, MA
|
Can you please share how to fix this error code 601.....
Here is my message
error code = 601; message="err";
additional data = [b_webt_shared:java.io.FileNotFoundException:Message Broker\IBMSoftware\disk\setup\3889e27ca5f79692c3662dc1172e6ecb\b_webt_shared_compressed_0 (The system cannot find the file specified)])
STACK_TRACE: 12
Help |
|
Back to top |
|
 |
jefflowrey |
Posted: Tue Apr 24, 2007 9:43 am Post subject: |
|
|
Grand Poobah
Joined: 16 Oct 2002 Posts: 19981
|
PFaulkner's problem, most likely, was that they were trying to install 6.0.1.1 Toolkit onto a machine with an earlier version of RAD already installed. If pfaulker had updated that RAD to 6.0.1.1ish, then likely it would have succeeded to install Toolkit onto that machine.
I think we don't have enough information about your particular problem to help yet. _________________ I am *not* the model of the modern major general. |
|
Back to top |
|
 |
pfaulkner |
Posted: Tue Apr 24, 2007 10:23 am Post subject: |
|
|
Master
Joined: 18 Mar 2002 Posts: 241 Location: Colorado, USA
|
Sorry I should have updated the forum with the fix.
I opened a PMR and IBM recommended the following:
1) Backup and edit the cdi_ref.properties file and remove the line:
c_webt_shared.products=wmbt
2) Uninstall their RAD installation
3) Check to see that the cdi_ref.properties file is removed.
If so, delete the RAD and Message Brokers Toolkit V6 install
directories.
4) Reinstall RAD6.0 and bring it back up to the RAD 6001 level
- Keep track of whether Language Pack option was selected when install
RAD6.0
5) Run the MB Toolkit V6 install again and when presented the option
of Language Packs, match what was selected for RAD. If RAD had no
Language Packs, then MB 60 should have no Language Packs (deselect) and
vice versa.
Steps 2) to 4) may be optional but if the user can do that, it would
ensure a working installation. There is a Rational defect about
uninstall that affects all Rational and shell shared products (including
Toolkit) and we are following up for workarounds/fixes. User may be
affected by this issue and to not hold them up, steps 2) to 4) can be
performed.
In our case, uninstalled RAD was not an option. I did step 1, and everything worked.
Hope this helps |
|
Back to top |
|
 |
wmqiadmin |
Posted: Tue Apr 24, 2007 11:55 am Post subject: |
|
|
 Disciple
Joined: 19 Jun 2005 Posts: 163 Location: epping UK
|
Hi,
Do you know where this file (cdi_ref.properties file) is located??
Even I am trying to install broker Toolkit with RSA Toolkit and its throwing errors. I have uninstall RSA but still its throwing different kinds of errors .
Thanks
wmqiadmin |
|
Back to top |
|
 |
ADV |
Posted: Wed Apr 25, 2007 5:01 am Post subject: Thanks for the reply |
|
|
Apprentice
Joined: 24 Apr 2007 Posts: 44 Location: Boston, MA
|
cdi_ref.properties file is in location C:\WINDOWS\IBM\RAC60\.sdpinst & size is 0 bytes. Means, property file is empty. What should I do? |
|
Back to top |
|
 |
|
|
 |
|
Page 1 of 1 |
|