Author Message
LH33
PostPosted: Tue Mar 07, 2006 1:11 pm    Post subject: Severe Abend Error Reply with quote

Master

Joined: 21 Nov 2002
Posts: 200

I have a message flow that takes an XML message and based on the content of a tag, calls a subflow that formats another XML message and sends it to the SendMail plug-in node to hopefully e-mail me. When it hits the SendMail plug-in node, it produces a Severe Abend Error. Can someone help to point me in the direction where I can look to see why the abend is occuring? Below is the trace of the message before it hits the SendMail node and also the abend error message:


Trace output: (
(0x01000000):Properties = (
(0x03000000):MessageSet = ''
(0x03000000):MessageType = ''
(0x03000000):MessageFormat = ''
(0x03000000):Encoding = 546
(0x03000000):CodedCharSetId = 437
(0x03000000):Transactional = TRUE
(0x03000000):Persistence = TRUE
(0x03000000):CreationTime = GMTTIMESTAMP '2006-02-24 17:44:28.780'
(0x03000000):ExpirationTime = -1
(0x03000000):Priority = 0
(0x03000000):ReplyIdentifier = X'000000000000000000000000000000000000000000000000'
(0x03000000):ReplyProtocol = 'MQ'
(0x03000000):Topic = NULL
)
(0x01000000):MQMD = (
(0x03000000):SourceQueue = 'DSPCH_ODL_CAD_ERROR'
(0x03000000):Transactional = TRUE
(0x03000000):Encoding = 546
(0x03000000):CodedCharSetId = 437
(0x03000000):Format = 'MQSTR '
(0x03000000):Version = 2
(0x03000000):Report = 0
(0x03000000):MsgType = 4
(0x03000000):Expiry = -1
(0x03000000):Feedback = 0
(0x03000000):Priority = 0
(0x03000000):Persistence = 1
(0x03000000):MsgId = X'414d51204745544d5131202020202020d7e2fd432012d869'
(0x03000000):CorrelId = X'000000000000000000000000000000000000000000000000'
(0x03000000):BackoutCount = 0
(0x03000000):ReplyToQ = ' '
(0x03000000):ReplyToQMgr = 'GETMQ1 '
(0x03000000):UserIdentifier = 'SYSTEM '
(0x03000000):AccountingToken = X'060101120000000000000000000000000000000000000000000000000000000b'
(0x03000000):ApplIdentityData = ' '
(0x03000000):PutApplType = 11
(0x03000000):PutApplName = '\Exe\XML\ConnectorAgents.exe'
(0x03000000):PutDate = DATE '2006-02-24'
(0x03000000):PutTime = GMTTIME '17:44:28.780'
(0x03000000):ApplOriginData = ' '
(0x03000000):GroupId = X'000000000000000000000000000000000000000000000000'
(0x03000000):MsgSeqNumber = 1
(0x03000000):Offset = 0
(0x03000000):MsgFlags = 0
(0x03000000):OriginalLength = -1
)
(0x01000010):XML = (
(0x01000000):Message = (
(0x01000000):From = (
(0x02000000): = 'Broker'
)
(0x01000000):To = (
(0x02000000): = 'lisa.holton@bge.com'
)
(0x01000000):Subject = (
(0x02000000): = 'MDS CreateJob Failed'
)
)
)
)

Abend Message: Abend Record for PID: 5556 TID: 0x11B8 on: Fri Feb 24 15:07:10 2006

---> Location <---
File: F:\build\S500_P\src\CommonServices\Win32\ImbAbend.cpp
Line: 1386
Function: ImbAbend::unhandledExceptionFilterInternal()
AbendAction: 3

---> Inserts <---
An Unhandled Exception detected in process 5556, on thread 0x11B8.
Type: EXCEPTION_ACCESS_VIOLATION (C0000005).
Address: 001B:0D0877F0.
The thread could not read from memory address 0x00000000.

---> Last Errors <---
Note these error codes are not necessarily reliable
GetLastError() returned: 0
errno returned: 0

---> Sys Info <---
Machine Name: PNET-GE-TMQ1
Process User Name: MQSIDB2T
No of Processors: 2
Processor Type: x86 Family 6 Model 10 Stepping 4
OS: Microsoft Windows 2000 Advanced Server Service Pack 4 (Build 2195)
Current Type: Multiprocessor Free
Command Line: "F:/WBIMB/bin/DataFlowEngine.exe" "GETMQ1" "ac1a2ff2-0101-0000-0080-c3de740b23fa" "MDSODL" "0"
CMVC: @(#) 1.18.1.1 CommonServices/Win32/ImbAbend.cpp, CommonServices, S500, S500-CSD03 03/10/16 20:33:50 [4/27/04 20:22:52]
Lib Version: 4.0.5.0

---> Process Status <---
Memory:
Usage Load: 49%
Total Physical Memory: 2147483647 bytes
Available Physical Memory: 1634152448 bytes
Total PageFile: 4294967295 bytes
Available PageFile: 2088337408 bytes
Total Virtual Memory: 2147352576 bytes
Available Virtual Memory: 1819185152 bytes

Working Set:
Min: 204800 bytes
Max: 1413120 bytes

Timings:
Creation Time: D-24 M-2 Y-2006 : 19:48:0.810
Kernel Time: 1656 ms
User Time: 7781 ms

---> Stack dump for the faulting thread (0x11B8), with malloc disallowed. <---
Registers:
EAX=0x00000000 EBX=0x0D9ADA58 ECX=0x00000000 EDX=0x00000000
ESI=0x0D094EF0 EDI=0x0D9AC6FC EIP=0x0D0877F0 ESP=0x0D9AC6F8
EBP=0x0D9AD130 EFlags=0x00010246
CS=0x001B DS=0x0023 SS=0x0023 ES=0x0023 FS=0x003B GS=0x0000

Stack Backtrace:
# ChildEBP RetAddr Param#1 Param#2 Param#3 Param#4 Fn-Loc'n : Module!Function+Offset [File Name # Line+Offset @ Address]
00 0D9AD130 0D08535B (0D0A9D10 0D0A9C18 0D0A9C78 0D098E54) 0D0877F0 : SendMailPlugIn!bipGetMessageflowNodeFactory+0x27d5<NLN:487>
01 0D9AD17C 0D0848E9 (0D0A4150 0D090019 0D0A9C18 0D0A9C78) 0D08535B : SendMailPlugIn!bipGetMessageflowNodeFactory+0x340<NLN:487>
02 0D9AD92C 2D963972 (0D0A3DC0 0D9ADA20 0D9AD9C8 0D9ADA38) 0D0848E9 : SendMailPlugIn!<No Symbol Found>, Error Code: 487 <NLN:487>
03 0D9ADB04 00ECB223 (0D9AE434 0D5DF220 0D5DF220 0BE19C20) 2D963972 : imbdfplg!ImbCniNode::evaluate+0x1e2 [F:\build\S500_P\src\DataFlowEngine\PluginInterface\ImbCniNode.cpp # 1282+0 @ 0x2D963972]
04 0D9ADB74 00ECB8FF (0D9AE434 0BE19C20 0D9AE434 00000001) 00ECB223 : DataFlowDLL!ImbDataFlowTerminal::evaluate+0x1c3 (FPO: [EBP: 0x0D5DF220] [1,22,3]) [F:\build\S500_P\src\DataFlowEngine\ImbDataFlowTerminal.cpp # 285+0 @ 0xECB223]
05 0D5DF220 0D5E2EB0 (0D5DDF30 00000000 0D5E2EB0 00000000) 00ECB8FF : DataFlowDLL!ImbDataFlowTerminal::callFlowDebugAPI+0x3cf [F:\build\S500_P\src\DataFlowEngine\ImbDataFlowTerminal.cpp # 382+0 @ 0xECB8FF]
06 2D975A7C 2D9717AC (2D9717A6 2D9717A0 2D97179A 2D971794) 0D5E2EB0 : ***StackWalk Warning: Module does not appear to exist. Following frames may be wrong. Error Code: 487*** <Unknown>!<No Symbol Found>, Error Code: 126 <NLN:126>
07 2D9717B2 25FF2D97 (2D975140 51B425FF 25FF2D97 2D9751B8) 2D9717AC : imbdfplg!ImbOwnedLogSource::logType+0x0<NLN:487>
08 510425FF 00000000 (00000000 00000000 00000000 00000000) 25FF2D97 : ***StackWalk Warning: Module does not appear to exist. Following frames may be wrong. Error Code: 299*** <Unknown>!<No Symbol Found>, Error Code: 126 <NLN:126>
Back to top
View user's profile Send private message
wschutz
PostPosted: Tue Mar 07, 2006 4:29 pm    Post subject: Reply with quote

Jedi Knight

Joined: 02 Jun 2005
Posts: 3316
Location: IBM (retired)

I'm not sure that Arjan watches this forum, you might want to e-mail him: avv@nl.ibm.com
_________________
-wayne
Back to top
View user's profile Send private message Send e-mail AIM Address
titus
PostPosted: Thu Mar 22, 2007 12:30 pm    Post subject: Reply with quote

Novice

Joined: 14 Oct 2002
Posts: 23

We had the same problem. As per IBM sendEmail plugin spawning the EG group where the sendEmail plugin resides. Which will in turn cause the broker to issue severe error.
We replaced this plugin. We created a JAVA compute node with the help of JAVA mail API to send out the email.
Back to top
View user's profile Send private message
jefflowrey
PostPosted: Thu Mar 22, 2007 12:51 pm    Post subject: Reply with quote

Grand Poobah

Joined: 16 Oct 2002
Posts: 19981

I was able to work around a similar problem with this node, by not using the <Line> tags, and just building one big <Body> string.


_________________
I am *not* the model of the modern major general.
Back to top
View user's profile Send private message
m.schneider
PostPosted: Mon Jul 09, 2007 2:35 am    Post subject: Reply with quote

Centurion

Joined: 10 Apr 2007
Posts: 132
Location: Germany

I have some similar problems, sending the following message I get an internal Broker error on my testserver. When I run the flow on my local development environment I get an expected tcp/ip connection error, because there is no smtp server installed.


<Message>
<From>testsender@test.de</From>
<To>testreceiver@test.de</To>
<Subject>Testmail vom Trade Manager</Subject>
<Body>(See attached file: xWMQ.txt)</Body>
<Encoding7Bit ContentType="text/plain" Name="xWMQ.txt">
<![CDATA[http://edi.services.ibm.com/mqseries/spec_sheets.shtml]]>
</Encoding7Bit>
</Message>


Stack Backtrace:
# ChildEBP RetAddr Param#1 Param#2 Param#3 Param#4 Fn-Loc'n : Module!Function+Offset [File Name # Line+Offset @ Address]
00 0CE4E544 0C90535F (0C9272E0 00000000 0C918690 0C918690) 0C90575C : SendMailPlugIn!bipGetMessageflowNodeFactory+0x63c<NLN:487>
01 0CE4E594 0C904855 (0C926DA8 0C910019 00000000 0C918690) 0C90535F : SendMailPlugIn!bipGetMessageflowNodeFactory+0x23f<NLN:487>
02 0CE4ED64 0C498C00 (0C922BE8 0CE4EEEC 0CE4EE8C 0CE4EF08) 0C904855 : SendMailPlugIn!<No Symbol Found>, Error Code: 487 <NLN:487>
03 0CE4EF60 2EDC8925 (0CE4F3D4 0C53EEF8 0C545C90 0C564B00) 0C498C00 : imbdfplg!?evaluate@ImbCniNode@@UAEAAVImbDataFlowNode@@ABVImbMessageAssembly@@PBVImbDataFlowTerminal@@@Z+0x260<NLN:487>
04 0CE4EFCC 2EDC9516 (0CE4F3D4 0C564B00 0C561710 0C5614E8) 2EDC8925 : MessageServices!?evaluate@ImbDataFlowTerminal@@QAEAAV1@ABVImbMessageAssembly@@@Z+0x165 (FPO: [EBP: 0x0CE4F00C] [1,21,0])<NLN:487>
05 0CE4F00C 2EDC875C (0CE4F3D4 0C53EEF8 0CE4F8EC 0C564A50) 2EDC9516 : MessageServices!?propagateInner@ImbDataFlowTerminal@@AAEXABVImbMessageAssembly@@PAV1@@Z+0x76<NLN:487>
06 0CE4F054 0C507F24 (0CE4F3D4 0C564AD8 0CE4FD88 0C564AD8) 2EDC875C : MessageServices!?propagate@ImbDataFlowTerminal@@QAEAAV1@ABVImbMessageAssembly@@@Z+0x1cc (FPO: [EBP: 0x0CE4F3D4] [1,11,4])<NLN:487>
07 0CE4F3D4 0C63B850 (0CE4F984 0CE4F8EC 0CE4F234 0CE4FA1C) 0C507F24 : imbdfsql!?evaluate@ImbComputeNode@@UAEAAVImbDataFlowNode@@ABVImbMessageAssembly@@PBVImbDataFlowTerminal@@@Z+0x794<NLN:487>
08 0C63B800 00000000 (00000001 0C63B930 0C562608 01000001) 0C63B850 : ***StackWalk Warning: Module does not appear to exist. Following frames may be wrong. Error Code: 487*** <Unknown>!<No Symbol Found>, Error Code: 126 <NLN:126>
Back to top
View user's profile Send private message
Vijji
PostPosted: Mon Jul 09, 2007 6:38 am    Post subject: Reply with quote

Voyager

Joined: 30 Aug 2005
Posts: 83

Hi ,

Did u people checked the previous posts on SendMailPlugin Node.
Check the below post
http://www.mqseries.net/phpBB2/viewtopic.php?t=28616&highlight=vijji



Cheers
Vijji
Back to top
View user's profile Send private message
m.schneider
PostPosted: Mon Jul 09, 2007 10:40 pm    Post subject: Reply with quote

Centurion

Joined: 10 Apr 2007
Posts: 132
Location: Germany

Yes, I already read previous posts on this topic, ...
Back to top
View user's profile Send private message
m.schneider
PostPosted: Tue Jul 10, 2007 2:03 am    Post subject: Reply with quote

Centurion

Joined: 10 Apr 2007
Posts: 132
Location: Germany

Did someone already use the sendmail plug-in with Windows Server 2003 Enterprise Edition?
Back to top
View user's profile Send private message
Display posts from previous:   
Post new topic  Reply to topic Page 1 of 1

MQSeries.net Forum Index » WebSphere Message Broker (ACE) Support » Severe Abend Error
Jump to:  



You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
Protected by Anti-Spam ACP
 
 


Theme by Dustin Baccetti
Powered by phpBB © 2001, 2002 phpBB Group

Copyright © MQSeries.net. All rights reserved.