Author |
Message
|
stewart |
Posted: Mon Dec 20, 2004 1:01 pm Post subject: BIP1758E |
|
|
 Newbie
Joined: 17 Aug 2004 Posts: 5 Location: washington DC
|
hi all
i am getting the following error while deploying the message flow:
BIP1758E: Invalid message flow type found when deploying message flows.
When deploying message flow data, an attempt was made by a message flow type to override the value of a nonexistent property of run-time message flow type Compute. The property in question is 'validateFixup'. The message flow type in error is the one that embeds Compute, and may be identified from label NORDICS_MF-GL001.3_V1.CreateEMWFMessage.
This is probably caused by a message flow type that corresponds to a run-time node having been replaced by a later version with different property names. Update the message flow type in error to use the correct property name. However if the problem persists, turn on Configuration Manager tracing to capture details of the problem, and contact your IBM support center. |
|
Back to top |
|
 |
kirani |
Posted: Mon Dec 20, 2004 1:41 pm Post subject: |
|
|
Jedi Knight
Joined: 05 Sep 2001 Posts: 3779 Location: Torrance, CA, USA
|
Please provide your Environment details. _________________ Kiran
IBM Cert. Solution Designer & System Administrator - WBIMB V5
IBM Cert. Solutions Expert - WMQI
IBM Cert. Specialist - WMQI, MQSeries
IBM Cert. Developer - MQSeries
|
|
Back to top |
|
 |
stewart |
Posted: Mon Dec 20, 2004 2:44 pm Post subject: |
|
|
 Newbie
Joined: 17 Aug 2004 Posts: 5 Location: washington DC
|
hi
my environment is:
WMQI 2.1
broker and configmgr on the same QMgr @win2000pro, DB2
logged in as admin too |
|
Back to top |
|
 |
kirani |
Posted: Mon Dec 20, 2004 3:19 pm Post subject: |
|
|
Jedi Knight
Joined: 05 Sep 2001 Posts: 3779 Location: Torrance, CA, USA
|
When exactly do you get this error? Is this message flow exported from different machine? If so, is it at the same CSD level as the server you are trying to import into? _________________ Kiran
IBM Cert. Solution Designer & System Administrator - WBIMB V5
IBM Cert. Solutions Expert - WMQI
IBM Cert. Specialist - WMQI, MQSeries
IBM Cert. Developer - MQSeries
|
|
Back to top |
|
 |
JT |
Posted: Mon Dec 20, 2004 3:35 pm Post subject: |
|
|
Padawan
Joined: 27 Mar 2003 Posts: 1564 Location: Hartford, CT.
|
|
Back to top |
|
 |
stewart |
Posted: Tue Dec 21, 2004 11:27 am Post subject: |
|
|
 Newbie
Joined: 17 Aug 2004 Posts: 5 Location: washington DC
|
thanks for referring to CSD
i created configmgr and broker before installing CSD. that's why i got the error.Now i deleted configmgr and recreated it. The problem is solved.
thanks all for help. |
|
Back to top |
|
 |
|