schweim
PostPosted: Tue Oct 19, 2004 9:27 am    Post subject: AMQCRSTA Process on Windows XP? Reply with quote

Newbie

Joined: 15 Jun 2004
Posts: 9
Location: Ohio

I had a question that someone here might be able to answer...

Can the AMQCRSTA process be run under Windows XP Pro? We are currently attempting to do load testing of our WMQ infrastructure using a Loderunner type tool and are attempting to simulate approximately 2000 channel pairs. We are running WMQ 5.3 Server with CSD05 on a Windows XP Pro workstation connecting to a queue manager on an AIX concentrator with WMQ 5.3 CSD05. We had tried to use RUNMQLSR but this seems to limit the number of concurrent connections on the workstation to 1200. If it is possible to run AMQCRSTA on WinXP, how might we do so? Thanks.

Matthew Schweitzer
Back to top
View user's profile Send private message
Nigelg
PostPosted: Wed Oct 20, 2004 3:52 am    Post subject: Reply with quote

Grand Master

Joined: 02 Aug 2004
Posts: 1046

amqcrsta is for UNIX platforms only.
I do not see any reason why runmqlsr should limit the number of connctions to 1200.
What error do you get when you reach that number of clients?
Have you set MaxChannels to 2000?
Back to top
View user's profile Send private message
schweim
PostPosted: Wed Oct 20, 2004 7:26 am    Post subject: Reply with quote

Newbie

Joined: 15 Jun 2004
Posts: 9
Location: Ohio

I will try that thanks. I wasn't aware of that setting on the QM itself. We did not get an error message specifically as we were simply informed by a vendor we were working with that there was a 1200 concurrent connection limit if using runmqlsr. So, if using the MaxChannel option, there is no logical limit to the maximum number of connections to a queue manager?
Back to top
View user's profile Send private message
PeterPotkay
PostPosted: Wed Oct 20, 2004 9:05 am    Post subject: Reply with quote

Poobah

Joined: 15 May 2001
Posts: 7722

schweim wrote:
So, if using the MaxChannel option, there is no logical limit to the maximum number of connections to a queue manager?


Ths O/S and the hardware are the limiting factor, not MQ, as long as you set the QM properties high enough.

The Performance Support Pack for Windows has test cases with many thousands of connections at the same time.
_________________
Peter Potkay
Keep Calm and MQ On
Back to top
View user's profile Send private message
schweim
PostPosted: Mon Nov 01, 2004 8:00 am    Post subject: Reply with quote

Newbie

Joined: 15 Jun 2004
Posts: 9
Location: Ohio

Well we did set the MaxChannel and MaxActiveChannel setting on the QM on the workstation, but we are definately encountering problems when we try to start more than 100 connections. We noticed that there are two runmqchl.exe processes spawned for each channel connection and this seems to be bogging down the box and preventing new connections from being made. We are running runmqlsr on the WS. Is there a threaded listner for the XP workstation that we could try? Any suggestions for starting several hundred connections at once?
Back to top
View user's profile Send private message
bower5932
PostPosted: Mon Nov 01, 2004 8:06 am    Post subject: Reply with quote

Jedi Knight

Joined: 27 Aug 2001
Posts: 3023
Location: Dallas, TX, USA

100 seems awfully suspicious since this is the default.
Back to top
View user's profile Send private message Send e-mail Visit poster's website AIM Address Yahoo Messenger
PeterPotkay
PostPosted: Mon Nov 01, 2004 8:11 am    Post subject: Reply with quote

Poobah

Joined: 15 May 2001
Posts: 7722

Did you restart the QM to pick up the changes?

Regardless, 2 runmqlsr processes for every channel seems wrong.
_________________
Peter Potkay
Keep Calm and MQ On
Back to top
View user's profile Send private message
Nigelg
PostPosted: Mon Nov 01, 2004 8:38 am    Post subject: Reply with quote

Grand Master

Joined: 02 Aug 2004
Posts: 1046

The threaded listener is runmqlsr, and RCVR channels always run as threads in amqrmppa.
runmqchl is the SDR channel process, and to get SDR channels to run as threads in amqrmppa, set MCATYPE(THREAD) in the SDR channel def.
Back to top
View user's profile Send private message
schweim
PostPosted: Mon Nov 01, 2004 10:24 am    Post subject: Reply with quote

Newbie

Joined: 15 Jun 2004
Posts: 9
Location: Ohio

We have a pair of sender and receiver channels and trying to start 150 pairs. I tried the MCATYPE(THREAD) in the sdr channel definition but we still see the 150 runmqchl processes running in taskmgr. Is there anything else we might try?
Back to top
View user's profile Send private message
Display posts from previous:   
Post new topic  Reply to topic Page 1 of 1

MQSeries.net Forum Index » General IBM MQ Support » AMQCRSTA Process on Windows XP?
Jump to:  



You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
Protected by Anti-Spam ACP
 
 


Theme by Dustin Baccetti
Powered by phpBB © 2001, 2002 phpBB Group

Copyright © MQSeries.net. All rights reserved.