Author |
Message
|
dcapodic |
Posted: Thu Jan 03, 2008 8:52 am Post subject: Multiple instances of CMF file in .BAR file.... |
|
|
Apprentice
Joined: 03 Sep 2003 Posts: 32
|
|
Back to top |
|
 |
mqmatt |
Posted: Thu Jan 03, 2008 8:58 am Post subject: |
|
|
 Grand Master
Joined: 04 Aug 2004 Posts: 1213 Location: Hursley, UK
|
Well, a BAR file is a zip-based file format, so file names must be unique inside it. Also, the Config Manager uses the file name to determine what needs replacing and what is new in an execution group.
So I think you'll need to add the flow multiple times with different names and then configure them individually.
Cheers
-Matt |
|
Back to top |
|
 |
dcapodic |
Posted: Thu Jan 03, 2008 9:03 am Post subject: |
|
|
Apprentice
Joined: 03 Sep 2003 Posts: 32
|
mqmatt wrote: |
Well, a BAR file is a zip-based file format, so file names must be unique inside it. Also, the Config Manager uses the file name to determine what needs replacing and what is new in an execution group.
So I think you'll need to add the flow multiple times with different names and then configure them individually.
Cheers
-Matt |
Thanks for the reply. I have actually tried exactly that....adding the flow, then renaming the CMF file and then adding in the same flow again, but instead of adding in the same flow (but now using a different name) it overwrites what is there. Your suggestion is exactly the way I would think it should work, but it doesn't
Not sure if it is a bug in the toolkit or a bug in the user! |
|
Back to top |
|
 |
spriet |
Posted: Thu Jan 03, 2008 11:54 am Post subject: |
|
|
Newbie
Joined: 15 Apr 2004 Posts: 4 Location: Toronto
|
What version are you running of the WMB toolkit?
Also is there any iFixes on the version that you are using?
Once I know this then I can try it and see why this might not be working. _________________ WebSphere Business Integration Application Connectivity Tools,
IBM Canada Lab,
email: spriet@ca.ibm.com |
|
Back to top |
|
 |
dcapodic |
Posted: Thu Jan 03, 2008 6:10 pm Post subject: |
|
|
Apprentice
Joined: 03 Sep 2003 Posts: 32
|
spriet wrote: |
What version are you running of the WMB toolkit?
Also is there any iFixes on the version that you are using?
Once I know this then I can try it and see why this might not be working. |
Thanks for the reply.
I am using version 6.0.2.0 of the toolkit. I have not applied any other fixes. |
|
Back to top |
|
 |
biswagourab |
Posted: Tue Jan 08, 2008 8:46 am Post subject: |
|
|
 Apprentice
Joined: 31 May 2005 Posts: 47 Location: London
|
Hi
My toolkit version is 6.0.0.1 , and I am able to do it. _________________ _________________
Biswa Gourab Malla
IBM Certified System Administrator - WebSphere MQ, v6.0
IBM Certified System Administrator - Websphere Message Broker v6.0
Last edited by biswagourab on Tue Jan 08, 2008 9:04 am; edited 2 times in total |
|
Back to top |
|
 |
biswagourab |
Posted: Tue Jan 08, 2008 8:48 am Post subject: |
|
|
 Apprentice
Joined: 31 May 2005 Posts: 47 Location: London
|
Hi
I tried to do the same and was able to do it.
The version I am at is
BIP8996I: Version: 6003
BIP8997I: Product: WebSphere Message Brokers
BIP8998I: CMVC Level: S600-CSD03 DH600-L60821.1
BIP8999I: Build Type: Production
Just remember to save the .BAR file once you rename the .cmf file, and then try adding the same message flow again.
Cheers
Biswa _________________ _________________
Biswa Gourab Malla
IBM Certified System Administrator - WebSphere MQ, v6.0
IBM Certified System Administrator - Websphere Message Broker v6.0 |
|
Back to top |
|
 |
spriet |
Posted: Tue Jan 08, 2008 8:53 am Post subject: Looks to be a problem on 602 |
|
|
Newbie
Joined: 15 Apr 2004 Posts: 4 Location: Toronto
|
This looks to be a problem on 602. A PMR just came in and we are looking into the issue.
Dave Spriet _________________ WebSphere Business Integration Application Connectivity Tools,
IBM Canada Lab,
email: spriet@ca.ibm.com |
|
Back to top |
|
 |
|