Author |
Message
|
virendra_k_singh |
Posted: Wed Jun 26, 2002 3:50 am Post subject: on nt server unable to create config manager |
|
|
Newbie
Joined: 26 Jun 2002 Posts: 9
|
Hi
I am stuck that when i try to create configmanager or brocker it gives windows error message
"unable to initiallize the application properly (some hexcode addres).click ok to terminate the application."
after reinstalling the mqsi problem remains same.
Have any one encounterd the same proble.....
Thanks & regards
virendra |
|
Back to top |
|
 |
TorpedoSTu |
Posted: Wed Jun 26, 2002 5:31 am Post subject: |
|
|
Acolyte
Joined: 14 Nov 2001 Posts: 73
|
What operating system are you on and at what sp level ?.
What version of DB2 are you running ?
Regs
Stuart |
|
Back to top |
|
 |
udaybho |
Posted: Wed Jun 26, 2002 9:29 am Post subject: |
|
|
Voyager
Joined: 09 May 2002 Posts: 94 Location: Chicago
|
Make sure that you belong to Administrator group while you are doing installation.
Did you tried creating configmgr using command promt ?
Uday Bhosle |
|
Back to top |
|
 |
virendra_k_singh |
Posted: Thu Jun 27, 2002 2:07 am Post subject: |
|
|
Newbie
Joined: 26 Jun 2002 Posts: 9
|
Thanks for your response .After reinstalletion i could create the cfgmanager and brocker .
But i am unabe to connect from controlcenter ...It gives the message could not get the response from the server.
I am using NT server 4.0 sp 6a.
everything is on same machine and quemanager.
[quote="TorpedoSTu"]What operating system are you on and at what sp level ?.
What version of DB2 are you running ?
Regs
Stuart[/quote] |
|
Back to top |
|
 |
kirani |
Posted: Thu Jun 27, 2002 6:00 am Post subject: |
|
|
Jedi Knight
Joined: 05 Sep 2001 Posts: 3779 Location: Torrance, CA, USA
|
Virendra,
Pl check whether your configuration manager service is running or not. Make sure your listner on config queue mgr is also running. What is the exact BIP error message you are getting? _________________ Kiran
IBM Cert. Solution Designer & System Administrator - WBIMB V5
IBM Cert. Solutions Expert - WMQI
IBM Cert. Specialist - WMQI, MQSeries
IBM Cert. Developer - MQSeries
|
|
Back to top |
|
 |
virendra_k_singh |
Posted: Thu Jun 27, 2002 5:21 pm Post subject: |
|
|
Newbie
Joined: 26 Jun 2002 Posts: 9
|
thanks for your response
I am getting following error message.
BIP1350E The current operation has timed out.
One or more requests have been sent to the Configuration Manager to process the current operation, but no reply has been received for the last request sent. (some more lines )
every thing is on same NT server machine. Q manger is running .listener is also running .
Config manager is started ...
Then why i am not able to connect .
DO I NEDD TO INSTALL MA88 on the machine ????
Thanks |
|
Back to top |
|
 |
kirani |
Posted: Thu Jun 27, 2002 6:43 pm Post subject: |
|
|
Jedi Knight
Joined: 05 Sep 2001 Posts: 3779 Location: Torrance, CA, USA
|
What version of MQSeries and MQSI are you using? Do you have latest CSD applied? _________________ Kiran
IBM Cert. Solution Designer & System Administrator - WBIMB V5
IBM Cert. Solutions Expert - WMQI
IBM Cert. Specialist - WMQI, MQSeries
IBM Cert. Developer - MQSeries
|
|
Back to top |
|
 |
virendra_k_singh |
Posted: Fri Jun 28, 2002 12:47 am Post subject: |
|
|
Newbie
Joined: 26 Jun 2002 Posts: 9
|
Hi i am using mqsi 2.1 ..
Is there any fixpack for mqsi 2.1 on nt server 4.0 sevice pack 6a.. |
|
Back to top |
|
 |
kirani |
Posted: Fri Jun 28, 2002 6:05 am Post subject: |
|
|
Jedi Knight
Joined: 05 Sep 2001 Posts: 3779 Location: Torrance, CA, USA
|
|
Back to top |
|
 |
CodeCraft |
Posted: Fri Jun 28, 2002 6:17 am Post subject: |
|
|
Disciple
Joined: 05 Sep 2001 Posts: 195
|
I would also recommend that anyone using WMQI gets the latest MA88 for the platform. Rumour has it that some MQ versions (5.1, 5.21) shipped with Java classes and some didn't (5.2?). Apply MA88. |
|
Back to top |
|
 |
virendra_k_singh |
Posted: Fri Jun 28, 2002 11:11 pm Post subject: |
|
|
Newbie
Joined: 26 Jun 2002 Posts: 9
|
Hi i have applied the fixpack for mqsi ...
Then even i am having the same problem....Control center is unable to connect the config manager .
I tried on nt workstation and it is working fine without any patches.... |
|
Back to top |
|
 |
Manikrish |
Posted: Fri Jun 28, 2002 11:38 pm Post subject: |
|
|
Apprentice
Joined: 19 Jun 2002 Posts: 35
|
Hi..
Check for ur Odbc Data Source..Check for ur DSN Config..,the database name in DSN Config is same as the one what u have been mentioned in databasename column of ur config Manager..Becoz,if u mention some other database name in config mgr and if u try to establish a connection with it, connection will get establish thru DSN to DB2, but it will not connect to database in DB2..Then it will show the error as "current operation has timed out" and there is no connection establish between ur control center and config mgr...Check it out
krishna |
|
Back to top |
|
 |
|