ASG
IBM
Zystems
Cressida
Icon
Netflexity
 
  MQSeries.net
Search  Search       Tech Exchange      Education      Certifications      Library      Info Center      SupportPacs      LinkedIn  Search  Search                                                                   FAQ  FAQ   Usergroups  Usergroups
 
Register  ::  Log in Log in to check your private messages
 
RSS Feed - WebSphere MQ Support RSS Feed - Message Broker Support

MQSeries.net Forum Index » WebSphere Message Broker (ACE) Support » MRM/XML Questions

Post new topic  Reply to topic
 MRM/XML Questions « View previous topic :: View next topic » 
Author Message
TonyD
PostPosted: Sun Jun 12, 2005 4:01 am    Post subject: MRM/XML Questions Reply with quote

Knight

Joined: 15 May 2001
Posts: 540
Location: New Zealand

I am working on an application that uses the MRM parser for XML messages, an area that I have not have much experience so far. I have come across a couple of issues that are probably due to that inexperience and would appreciate comment...I have read the 'Help' topics but sometimes they are not totally clear.

1. I am mapping from one schema to another. I have a complex element as follows:

Code:

      <Client>
         <ClientIdentifier>
            <IdentifierType>XYZ</IdentifierType>
            <IdentifierValue>99999999</IdentifierValue>
         </ClientIdentifier>



'ClientIdentifier' is defined as 'minOccurs=0 maxOccurs=Unbounded' , IdentifierType and Identifier Value are defined as 'minOccurs=1'. In other words, if there is a 'ClientIdentifier' it must contain 1 * IdentifierType and 1 * Identifiervalue'!
The input message does not contain a 'ClientIdentifier' element. The ESQL recognises that the subordinate elements are not present and sets them to 'NULL' as would be expected:

Code:


Assigning NULL to 'OutputRoot.MRM.cmdm:CMDMDataEntry[indexEntryOut].cmdm:Clients.cmdm:Client[indexClientOut].cmdm:ClientIdentifier.cmdm:IdentifierType', thus deleting it.
.....
Assigning NULL to 'OutputRoot.MRM.cmdm:CMDMDataEntry[indexEntryOut].cmdm:Clients.cmdm:Client[indexClientOut].cmdm:ClientIdentifier.cmdm:IdentifierValue', thus deleting it.
...



However the ouput message fails validation as it appears that the non-mandatory parent element 'ClientIdentifier' has been instantiated as an empty element.

Code:

                                             (0x01000013)http://www.xyz/Messages/CMDM/2005/05/CMDMXMLSchema_52:Clients          = (
                                               (0x01000013)http://www.xyz/Messages/CMDM/2005/05/CMDMXMLSchema_52:Client = (
                                                 (0x01000013)http://www.xyzMessages/CMDM/2005/05/CMDMXMLSchema_52:ClientIdentifier =
                                                 (0x03000013)http://www.xyz/Messages/CMDM/2005/05/CMDMXMLSchema_52:FamilyName               = 'Jones 5'


The validation failure occurs because 'ClientIdentifier' does not contain its mandatory elements. My questions is, how do I prevent the empty element being created.

2. I have noticed that, when with respect to the above complex element when it DOES contain the two subordinate elements, I test 'IF....ClientIdentifier IS NULL' I get a 'TRUE' result, which makes things difficult. Testing CARDINALITY appears to be the only way to get a predictable result.

I have read the various sections in 'Help' (CSD04 level) with respect to NULL handling without understanding the behaviour that I have described above. I woud therefore be grateful for any explanation/comment/suggestions.
Back to top
View user's profile Send private message Send e-mail
jefflowrey
PostPosted: Sun Jun 12, 2005 12:38 pm    Post subject: Reply with quote

Grand Poobah

Joined: 16 Oct 2002
Posts: 19981

Can we see your code where you are mapping from one to the other?
_________________
I am *not* the model of the modern major general.
Back to top
View user's profile Send private message
TonyD
PostPosted: Sun Jun 12, 2005 3:46 pm    Post subject: Reply with quote

Knight

Joined: 15 May 2001
Posts: 540
Location: New Zealand

Code:

            SET OutputRoot.MRM.cmdm:CMDMDataEntry[indexEntryOut].cmdm:Clients.cmdm:Client[indexClientOut].cmdm:ClientIdentifier.cmdm:IdentifierValue =
            InputRoot.MRM.eai:Clients.eai:Client[indexClientIn].eai:ClientIdentifier.eai:IdentifierValue;
            SET OutputRoot.MRM.cmdm:CMDMDataEntry[indexEntryOut].cmdm:Clients.cmdm:Client[indexClientOut].cmdm:ClientIdentifier.cmdm:IdentifierType =
            UPPER(SUBSTRING(InputRoot.MRM.eai:Clients.eai:Client[indexClientIn].eai:ClientIdentifier.eai:IdentifierType FROM 1 FOR 10));
Back to top
View user's profile Send private message Send e-mail
TonyD
PostPosted: Sun Jun 12, 2005 10:47 pm    Post subject: Solved! Reply with quote

Knight

Joined: 15 May 2001
Posts: 540
Location: New Zealand

'ClientIdentifier' in the inbound message schema was defined as 'maxOccurs=1' and in the outbound message schema as 'maxOccurs=unbounded'. Altering the inbound one to 'unbounded' also and mapping between the arrays fixed the problem.
Back to top
View user's profile Send private message Send e-mail
Display posts from previous:   
Post new topic  Reply to topic Page 1 of 1

MQSeries.net Forum Index » WebSphere Message Broker (ACE) Support » MRM/XML Questions
Jump to:  



You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
Protected by Anti-Spam ACP
 
 


Theme by Dustin Baccetti
Powered by phpBB © 2001, 2002 phpBB Group

Copyright © MQSeries.net. All rights reserved.