PostPosted: Tue Jan 08, 2002 12:07 am    Post subject: Reply with quote

Acolyte

Joined: 01 Dec 2001
Posts: 74



Which compiler should I use so that the sample programs given with MQSeries work without any problems??
I get compilation errors in 2 copy books when i try to compile the sample cobol program amqs0put10.cbl.I have MQSeries v5.2 installed on nt 4.0.

Thanks and Regards,
Vandana
Back to top
View user's profile Send private message
StefanSievert
PostPosted: Tue Jan 08, 2002 1:53 pm    Post subject: Reply with quote

Partisan

Joined: 28 Oct 2001
Posts: 333
Location: San Francisco

Vandana,
I have sucessfully used Microfocus Cobol on NT to compile MQ applications. What are the errors you receive, can you please provide more details?
Cheers,
Stefan

_________________
Stefan Sievert
IBM Certified * WebSphere MQ
Back to top
View user's profile Send private message
vandana
PostPosted: Tue Jan 08, 2002 10:02 pm    Post subject: Reply with quote

Acolyte

Joined: 01 Dec 2001
Posts: 74

Hi,
Thanks a lot.
I've been hunting for the answer since a very long time.
i tried compiling the amq0put0.cbl.
using Micro Focus COBOL/2 Version 1.1.0 L2.0
compiler.
i get the following compilation error.
i verified that these four variables were
declared in the following copy books.

1)CMQODV.CPY
2)CMQPMOV.CPY.

1608 15 MQOD-OBJECTRECPTR POINTER VALUE NULL.
* 44-S************************************************
* Literal expected
1610 15 MQOD-RESPONSERECPTR POINTER VALUE NULL.
* 44-S************************************************
* Literal expected
1779 15 MQPMO-PUTMSGRECPTR POINTER VALUE NULL.
* 44-S***********************************************
* Literal expected
1781 15 MQPMO-RESPONSERECPTR POINTER VALUE NULL.
* 44-S***********************************************
* Literal expected
Then i removed VALUE NULL and just kept the declaration as
POINTER(for the four variables )in the copy books.

I've copied all the copy books and the library files
in the same path as that of the cbl files so that the problem
of path of copy books and library files does not arise.

Then I compiled the program using the following command
cobol amq0put0;
The compilation now worked fine.

Then I linked the program using the following command
link amq0put0.obj;mqmcb32



The exe file gets generated and when i run it,
it asks me the Name of the target Queue but further
stops when the MQConn statement is encountered.
The following is the error I get.

D:MQSeriestoolscobolsamples>amq0put0
AMQ0PUT0 start
Please enter the name of the target queue
Queue1


Failed to find program MQCONN.EXE
Run time error number: 173
What could be the reason?


Thanks and Regards,
Vandana


Back to top
View user's profile Send private message
bower5932
PostPosted: Thu Jan 17, 2002 2:12 pm    Post subject: Reply with quote

Jedi Knight

Joined: 27 Aug 2001
Posts: 3023
Location: Dallas, TX, USA

Vandana,

Try adding LITLINK to your compile statment:

cobol amq0put0 LITLINK

I found an internal problem that was similar to yours and was resolved with the LITLINK.

Ron Bower
Back to top
View user's profile Send private message Send e-mail Visit poster's website AIM Address Yahoo Messenger
vandana
PostPosted: Tue Feb 05, 2002 8:01 pm    Post subject: Reply with quote

Acolyte

Joined: 01 Dec 2001
Posts: 74

Hi ,
i did compile it using LITLINK.
but i don't have cblink.exe
so if i link using link.exe specifying
the appropriate lib i.e

link amq0put0 ;mqmcb32.lib

but then i get a runtime error.

but i gives me the following error.

Microsoft (R) Segmented-Executable Linker Version 5.02.05
Copyright (C) Microsoft Corp 1984-1988. All rights reserved.


AMQ0PUT0.OBJ(AMQ0PUT0) : error L2029 : 'MQOPE' : unresolved external
AMQ0PUT0.OBJ(AMQ0PUT0) : error L2029 : 'MQPU' : unresolved external
AMQ0PUT0.OBJ(AMQ0PUT0) : error L2029 : 'MQDIS' : unresolved external
AMQ0PUT0.OBJ(AMQ0PUT0) : error L2029 : 'MQCON' : unresolved external
AMQ0PUT0.OBJ(AMQ0PUT0) : error L2029 : 'MQCLOS' : unresolved external

so i had to proceec compiling
without teh LITLINK option.

perhaps there is some variation
in the compiler that i'm using.



_________________


[ This Message was edited by: vandana on 2002-02-05 20:02 ]

[ This Message was edited by: vandana on 2002-02-05 20:05 ]
Back to top
View user's profile Send private message
Display posts from previous:   
Post new topic  Reply to topic Page 1 of 1

MQSeries.net Forum Index » IBM MQ API Support » Microfocus cobol compiler
Jump to:  



You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
Protected by Anti-Spam ACP
 
 


Theme by Dustin Baccetti
Powered by phpBB © 2001, 2002 phpBB Group

Copyright © MQSeries.net. All rights reserved.