Posted: Sun Sep 26, 2010 4:21 pm Post subject: 'gsk_attribute_set_enum - GSK_USE_SOC_MUTEX'
Newbie
Joined: 18 Jul 2010 Posts: 4
Hi All,
I am experiencing the below error while trying to start my sender channel.
This is as part of my DR test, i replicate my production box here.
I copied the SSL folder to the DR queue manager, restarted the MQ and
refreshed the SSL security.
The production is working fine with ouut any issues.
Any information is much appreciated.
Process(4668.21) User(mqm) Program(amqrmppa)
Host(*********)
AMQ9620: Internal error on call to SSL function on channel '????'.
EXPLANATION:
An error indicating a software problem was returned from a function which is
used to provide SSL support. The error code returned was '701'. The function
call was 'gsk_attribute_set_enum - GSK_USE_SOC_MUTEX'. The channel is '????';
in some cases its name cannot be determined and so is shown as '????'. The
channel did not start.
ACTION:
Collect the items listed in the 'Problem determination' section of the System
Administration manual and use either the WMQ Support site:
http://www.ibm.com/software/integration/wmq/support/, or IBM Support Assistant
(ISA): http://www.ibm.com/software/support/isa/, to see whether a solution is
already available. If you are unable to find a match, contact your IBM suppo[/b]
Well just copying the SSL folder would only do in very specific circumstances.
If your DR is at a different level / fix pack you could run into SSL problems as the gskit levels may not be the same... I also hope that you have the same qmgr names in DR as in the regular network. (this also means you can't run both at the same time...)
And you need of course to define the correct environment (JAVA_HOME).