Table 48 presents a worksheet listing all the parameters needed to set up communication from iSeries to one of the other WebSphere MQ platforms. The worksheet shows examples of the parameters, which have been tested in a working environment, and leaves space for you to fill in your own values. An explanation of the parameter names follows the worksheet. Use the worksheet in this chapter in conjunction with the worksheet in the chapter for the platform to which you are connecting.
Use the following worksheet to record the values you will use for this
configuration. Where numbers appear in the Reference column they
indicate that the value must match that in the appropriate worksheet elsewhere
in this book. The examples that follow in this chapter refer back to
the values in the ID column of this table. The entries in the Parameter
Name column are explained in Explanation of terms.
Table 48. Configuration worksheet for SNA on an iSeries system
ID | Parameter Name | Reference | Example Used | User Value |
---|---|---|---|---|
Definition for local node | ||||
(1) | Local network ID |
| NETID |
|
(2) | Local control point name |
| AS400PU |
|
(3) | LU name |
| AS400LU |
|
(4) | LAN destination address |
| 10005A5962EF |
|
(5) | Subsystem description |
| QCMN |
|
(6) | Line description |
| TOKENRINGL |
|
(7) | Resource name |
| LIN041 |
|
(8) | Local Transaction Program name |
| MQSERIES |
|
Connection to an OS/2 system
The values in this section must match those used in Table 15, as indicated. | ||||
(9) | Network ID | (2) | NETID |
|
(10) | Control point name | (3) | OS2PU |
|
(11) | LU name | (6) | OS2LU |
|
(12) | Controller description |
| OS2PU |
|
(13) | Device |
| OS2LU |
|
(14) | Side information |
| OS2CPIC |
|
(15) | Transaction Program | (8) | MQSERIES |
|
(16) | LAN adapter address | (10) | 10005AFC5D83 |
|
(17) | Mode | (17) | #INTER |
|
Connection to a Windows system
The values in this section must match those used in Table 17, as indicated. | ||||
(9) | Network ID | (2) | NETID |
|
(10) | Control point name | (3) | WINNTCP |
|
(11) | LU name | (5) | WINNTLU |
|
(12) | Controller description |
| WINNTCP |
|
(13) | Device |
| WINNTLU |
|
(14) | Side information |
| NTCPIC |
|
(15) | Transaction Program | (7) | MQSERIES |
|
(16) | LAN adapter address | (9) | 08005AA5FAB9 |
|
(17) | Mode | (17) | #INTER |
|
Connection to an AIX system
The values in this section must match those used in Table 21, as indicated. | ||||
(9) | Network ID | (1) | NETID |
|
(10) | Control point name | (2) | AIXPU |
|
(11) | LU name | (4) | AIXLU |
|
(12) | Controller description |
| AIXPU |
|
(13) | Device |
| AIXLU |
|
(14) | Side information |
| AIXCPIC |
|
(15) | Transaction Program | (6) | MQSERIES |
|
(16) | LAN adapter address | (8) | 123456789012 |
|
(17) | Mode | (14) | #INTER |
|
Connection to an HP-UX system
The values in this section must match those used in Table 24, as indicated. | ||||
(9) | Network ID | (4) | NETID |
|
(10) | Control point name | (2) | HPUXPU |
|
(11) | LU name | (5) | HPUXLU |
|
(12) | Controller description |
| HPUXPU |
|
(13) | Device |
| HPUXLU |
|
(14) | Side information |
| HPUXCPIC |
|
(15) | Transaction Program | (7) | MQSERIES |
|
(16) | LAN adapter address | (8) | 100090DC2C7C |
|
(17) | Mode | (17) | #INTER |
|
Connection to an AT&T GIS UNIX system
The values in this section must match those used in Table 26, as indicated. | ||||
(9) | Network ID | (2) | NETID |
|
(10) | Control point name | (3) | GISPU |
|
(11) | LU name | (4) | GISLU |
|
(12) | Controller description |
| GISPU |
|
(13) | Device |
| GISLU |
|
(14) | Side information |
| GISCPIC |
|
(15) | Transaction Program | (5) | MQSERIES |
|
(16) | LAN adapter address | (8) | 10007038E86B |
|
(17) | Mode | (15) | #INTER |
|
Connection to a Solaris system
The values in this section must match those used in Table 28, as indicated. | ||||
(9) | Network ID | (2) | NETID |
|
(10) | Control point name | (3) | SOLARPU |
|
(11) | LU name | (7) | SOLARLU |
|
(12) | Controller description |
| SOLARPU |
|
(13) | Device |
| SOLARLU |
|
(14) | Side information |
| SOLCPIC |
|
(15) | Transaction Program | (8) | MQSERIES |
|
(16) | LAN adapter address | (5) | 08002071CC8A |
|
(17) | Mode | (17) | #INTER |
|
Connection to an z/OS system without CICS
The values in this section must match those used in Table 33, as indicated. | ||||
(9) | Network ID | (2) | NETID |
|
(10) | Control point name | (3) | MVSPU |
|
(11) | LU name | (4) | MVSLU |
|
(12) | Controller description |
| MVSPU |
|
(13) | Device |
| MVSLU |
|
(14) | Side information |
| MVSCPIC |
|
(15) | Transaction Program | (7) | MQSERIES |
|
(16) | LAN adapter address | (8) | 400074511092 |
|
(17) | Mode | (6) | #INTER |
|
Connection to a VSE/ESA system
The values in this section must match those used in Table 50, as indicated. | ||||
(9) | Network ID | (1) | NETID |
|
(10) | Control point name | (2) | VSEPU |
|
(11) | LU name | (3) | VSELU |
|
(12) | Controller description |
| VSEPU |
|
(13) | Device |
| VSELU |
|
(14) | Side information |
| VSECPIC |
|
(15) | Transaction Program | (4) | MQ01 | MQ01 |
(16) | LAN adapter address | (5) | 400074511092 |
|
(17) | Mode |
| #INTER |
|
See Table 47 for more information.
The local node has been partially configured as part of the OS/400 installation. To display the current network attributes enter the command DSPNETA.
If you need to change these values use the command CHGNETA. An IPL may be required to apply your changes.
+--------------------------------------------------------------------------------+
| Display Network Attributes |
| System: AS400PU |
| Current system name . . . . . . . . . . . . . . : AS400PU |
| Pending system name . . . . . . . . . . . . . : |
| Local network ID . . . . . . . . . . . . . . . . : NETID |
| Local control point name . . . . . . . . . . . . : AS400PU |
| Default local location . . . . . . . . . . . . . : AS400LU |
| Default mode . . . . . . . . . . . . . . . . . . : BLANK |
| APPN node type . . . . . . . . . . . . . . . . . : *ENDNODE |
| Data compression . . . . . . . . . . . . . . . . : *NONE |
| Intermediate data compression . . . . . . . . . : *NONE |
| Maximum number of intermediate sessions . . . . : 200 |
| Route addition resistance . . . . . . . . . . . : 128 |
| Server network ID/control point name . . . . . . : NETID NETCP |
| |
| |
| |
| |
| |
| More... |
| Press Enter to continue. |
| |
| F3=Exit F12=Cancel |
+--------------------------------------------------------------------------------+
Check that the values for Local network ID ((1)), Local control point name ((2)), and Default local location ((3)), correspond to the values on your worksheet.
Type WRKHDWRSC TYPE(*CMN) and press Enter. The Work with Communication Resources panel is displayed. The value for Resource name is found as the Token-Ring Port. It is LIN041 in this example.
+--------------------------------------------------------------------------------+
| Work with Communication Resources |
| System: AS400PU |
|Type options, press Enter. |
| 2=Edit 4=Remove 5=Work with configuration description |
| 7=Add configuration description ... |
| |
| Configuration |
|Opt Resource Description Type Description |
| CC02 2636 Comm Processor |
| LIN04 2636 LAN Adapter |
| LIN041 TOKENRINGL 2636 Token-Ring Port |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| |
| Bottom |
|F3=Exit F5=Refresh F6=Print F11=Display resource addresses/statuses |
|F12=Cancel F23=More options |
| |
+--------------------------------------------------------------------------------+