The transaction process appears to be working correctly with the exception of an error that occurs when the END record reaches the output node. This error does not impact the actual processing within the message flow, however it does cause this END record to be a rolled-back to the input node.
Error with Custom Wire Format: message set 'DOUU7QG09S001'; message 'TRANSACTION_1'; parent element ''; current element '{5}'; function name 'CWFWorker::write'; error code '0'.
Custom Wire Format General Error. Record the full details provided with this message and contact your IBM support center.
An IMB syntax node Type Error has occurred during writing.
Error: Unknown or Invalid Type found in IMB Tree. A call to getData() on a MtiImbSyntaxElement has found a type associated with an ImbValue which it cannot handle. This is an internal error. Gather trace logs and contact support detailing what operations were performed. Examine any ESQL to see what type of manipulation occurred on elements. Review further error messages for an indication to the cause of the errors.
The message flow has been rolled-back and, if the message was being processed in a unit of work, it will remain on the input queue to be processed again.