Author Message
ghoshly
PostPosted: Wed Apr 16, 2014 6:40 am    Post subject: What is the correct way to detect primary/secondary instance Reply with quote

Partisan

Joined: 10 Jan 2008
Posts: 325

Hello,

Need suggestion on WMB V8.0.0.2 with extreme scale for cache.

We have a single broker running in multi-instance mode. Instance1 is running with cache data in server1 and instance2 is stand by in server2.
Our code looks for data in cache, if data is not available in cache, it performs database lookup.
During failover instance2 becomes active but is unable to access cache. (Limitation confirmed by IBM through PMR because of single broker)

When wmb code in instance2 tries to connect to cache, it takes almost 30 seconds to respond with the error (Connection exception). Is there any retry attempt being performed which we can configure?
Code:
2014-04-16 07:50:33.692176     6349   UserTrace   BIP2539I: Node '': Evaluating expression ''CH_MapKey'' at ('.ICE_ProfileLoader_Update_ICE_Profile.Main', '70.57'). This resolved to ''CH_MapKey''. The result was '''TMCInvoicingIRExportUSAEI0050TMCGetIRMessage'''.
2014-04-16 07:51:03.720840     6349   UserTrace   BIP2918I: Node 'ICE_ProfileLoader.Update_ICE_Profile': Executing Java Method ''com.java.cache.flow.MBGlobalMapWrapper.get'' derived from ('Utils.PROC_getMBGlobalMapWrapper', '1.4'). Parameters passed '''TMCInvoicingIRExportUSAEI0050TMCGetIRMessage',  'RequestDataMap',  REFERENCE''. Resulting parameter values '''TMCInvoicingIRExportUSAEI0050TMCGetIRMessage',  'RequestDataMap',  REFERENCE''. Return value '''<com.ibm.broker.plugin.MbRecoverableException class:MbEmbeddedCacheConnection method:MbEmbeddedCacheConnection source:BIPmsgs key:7164 >'''.


What would be the best way to identify the broker instance from esql code itself so that when it is instance2 (Initial passive instance) code does not attempts to connect with cache?

Workaround -
Through java we can identify the broker host name and through that we can make out the current server, but certainly not the best way.
Back to top
View user's profile Send private message
fjb_saper
PostPosted: Wed Apr 16, 2014 9:10 am    Post subject: Reply with quote

Grand High Poobah

Joined: 18 Nov 2003
Posts: 20696
Location: LI,NY

check with IBM. However I believe that when you set the cache policy you can specify "localhost". So if you really do run only one broker in the environment, setting the listener host to 'localhost' should allow you to find the global cache on which ever host the broker is currently active...
_________________
MQ & Broker admin
Back to top
View user's profile Send private message Send e-mail
ghoshly
PostPosted: Wed Apr 16, 2014 10:34 pm    Post subject: Reply with quote

Partisan

Joined: 10 Jan 2008
Posts: 325

Hi,

Already tried with localhost or virtual IP (VIP) but no luck. IBM confirmed, its would be possible in IIB only.

Hence trying to identify the instance either through esql or java api.
Back to top
View user's profile Send private message
ghoshly
PostPosted: Mon Apr 21, 2014 7:21 am    Post subject: How to reduce time out??? Reply with quote

Partisan

Joined: 10 Jan 2008
Posts: 325

Quote:
When wmb code in instance2 tries to connect to cache, it takes almost 30 seconds to respond with the error (Connection exception). Is there any retry attempt being performed which we can configure?



Through configuration, can we reduce the time out period WMB cache takes before throwing exception while connecting to cache from secondary server.
Back to top
View user's profile Send private message
Display posts from previous:   
Post new topic  Reply to topic Page 1 of 1

MQSeries.net Forum Index » WebSphere Message Broker (ACE) Support » What is the correct way to detect primary/secondary instance
Jump to:  



You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
Protected by Anti-Spam ACP
 
 


Theme by Dustin Baccetti
Powered by phpBB © 2001, 2002 phpBB Group

Copyright © MQSeries.net. All rights reserved.