kishankumar.v
PostPosted: Mon Dec 17, 2001 1:16 am    Post subject: Reply with quote

Apprentice

Joined: 26 Nov 2001
Posts: 47

Hi Folks,
I was able to successfully able to create the configuration manager..but when I try to connection it from the control center it is giving the following Timeout error

"BIP1350E: The current operation has timed out.

One or more requests have been sent to the Configuration Manager to process the current operation, but no reply has been received for the last request sent.

Either your request has queued up behind a long-running request by another user, or the Configuration Manager has stopped. Check that it is up and running then retry the operation. Because the link to the Configuration Manager is via MQSeries, it is important to note that the original operation may have fully completed, or have partly completed, even though no reply was received in the allotted time. The results of the retried operation should indicate this, and will determine subsequent actions. For example, if a check-in operation timed out then the update may have occurred, but the object may still be locked. A subsequent check-in would then fail with a locked response. The action would then be to unlock the object. "
Can you please suggest what may be the reason for this and a suitable fix. Iam not able to move forward.

Thanks In Advance,
V.Kishan Kumar
Back to top
View user's profile Send private message Send e-mail
cronydude
PostPosted: Mon Dec 17, 2001 1:27 am    Post subject: Reply with quote

Voyager

Joined: 11 Nov 2001
Posts: 85
Location: US

hi kishan,
there may be many reasons for the problem u r facing.u should have been more specific in describing ur problem.check for the following:

Check whether u have started all ur services, particularly config manager.

if u have reinstalled MQSI(probably after some problem) without deleting ur config manager database, u may face the above problem.try creating new database n new config manager.

regards
crony



Back to top
View user's profile Send private message
kishankumar.v
PostPosted: Mon Dec 17, 2001 1:39 am    Post subject: Reply with quote

Apprentice

Joined: 26 Nov 2001
Posts: 47

Thanks cronydude,
The problem was I dint start the config manager..Another question is .. can the config manager be started by other means than giving the mqsi command.? say through control center.

Kishan
Back to top
View user's profile Send private message Send e-mail
cronydude
PostPosted: Mon Dec 17, 2001 1:51 am    Post subject: Reply with quote

Voyager

Joined: 11 Nov 2001
Posts: 85
Location: US

hi kishan,
the other way is thro' WINNT services.its not possible from control centre.

regards
crony

[ This Message was edited by: cronydude on 2001-12-17 01:53 ]
Back to top
View user's profile Send private message
Display posts from previous:   
Post new topic  Reply to topic Page 1 of 1

MQSeries.net Forum Index » WebSphere Message Broker (ACE) Support » Configuration Manager Connection error
Jump to:  



You cannot post new topics in this forum
You cannot reply to topics in this forum
You cannot edit your posts in this forum
You cannot delete your posts in this forum
You cannot vote in polls in this forum
Protected by Anti-Spam ACP
 
 


Theme by Dustin Baccetti
Powered by phpBB © 2001, 2002 phpBB Group

Copyright © MQSeries.net. All rights reserved.